Hepa Filter
Cleanroom filtration is required in a broad range of industrial, semiconductor, nuclear, pharmaceutical, and biomedical applications. Multiple product configurations are used including panels, compact filters, and deep-pleat applications.
According to the FDA, HEPA filters have Clean efficiency of 99.97 % to 99.99 % when tested using the dioctyl phthalate (DOP) test with a particle size of 0.3 microns.This means that these filters can remove all yeast, mold, bacteria and other particles that are larger than 0.3 microns. The FDA recommends use HEPA filters in areas where RF-RTE foods are processed or exposed and others.
Hepa Filter
The features of this model include:
- Media:Wet-laid glass fiber
- Frame:aluminum or Galvanized steel
- Separator: paper or aluminum.
- Low initial resistance with high efficiency at rated volume
- Easy installation and guaranteed sealing performance
- Leakage testing by unit before leaving factory and provide testing report
- Efficiency:H11(EN1822),95% @ MPPS 99% @ 0.3um
- H13(EN1822),99.95% @ MPPS 99.99% @ 0.3um
- H14(EN1822),99.995% @ MPPS 99.999% @ 0.3um
- The filter shall be approved by UL Classified
- Recommended final Pressure drop:600Pa
- Quality
- Filters are made in accordance with the requirements of the ISO 9001 Quality Management System, which ensures that the product maintains the highest quality at all times.
Applications
- HEPA filters are used for terminal filtration in environments and industries requiring
- extremely high level levels of cleanliness.
- electronics and semiconductor
- manufacturing.
- precision machinery.
- pharmaceuticals.
- hospitals.
- food processing.
Specifications
MODEL | Overall Dim | Air Flow | Speed | Air flow/Resistance. | Final Resis. | |
---|---|---|---|---|---|---|
W x H x D | M3/Hr/pa | m/s | M3/hr/pa | M3/hr/pa | pa | |
HEPA10 | 610x1220x120 | 1500/230 | 0.55 | 2200/315 | 2400/375 | 500 |
HEPA20 | 610x610x120 | 1000/230 | 0.75 | 750/170 | 1200/275 | 500 |
HEPA30 | 610x915x150 | 1500/230 | 0.75 | 1100/170 | 1800/275 | 500 |
HEPA40 | 484x484x220 | 1000/230 | 1.17 | 630/145 | 1550/350 | 500 |
HEPA50 | 610x610x220 | 1600/230 | 1.18 | 1000/145 | 2500/350 | 500 |
HEPA60 | 610x610x292 | 2200/230 | 1.64 | 1550/150 | 3400/350 | 500 |
HEPA70 | 610x610x292 | 3300/105 | 2.46 | 2500/80 | 4000/125 | 500 |
HEPA80 | 610x915x292 | 4950/106 | 2.46 | 3800/80 | 6000/125 | 500 |
Hepa Filter Efficiency ,EN1822 | ◼Model -HEPA10 TO HEPA60 is H13 | |||||
◼Model -HEPA70 TO HEPA80 is F8 | ||||||
Usage/Application: | ◼HEPA filters are used for terminal filtration in environments and industries requiring◼ Extremely high level levels of cleanliness.◼ Electronics and semiconductor ◼ Manufacturing ◼ Precision machinery ◼ Pharmaceuticals ◼ Hospitals ◼ Food processing. |
For any other capacity contact factory. Due to continues improvements, specifications are subject to change without notification.
Unit Conversion
1 cfm = 28.3168 L/min
1 cfm = 1.699 cu.m/h.